Sizing Guide

How to Tell What Size AC Unit You Have (It's Hidden in the Model Number)

By the HVAC Calc Hub Engineering Team · Updated October 5, 2026 · 7 min read

The quick answer: find the two digits in your model number that divide evenly by 12. That number is your capacity in thousands of BTU per hour. So 36 means 36,000 BTU/h, which is 3 tons (one ton of cooling equals 12,000 BTU/h). The number is sitting on a metal plate on your outdoor unit right now, and it takes about thirty seconds to read.

The residential tonnage ladder

Almost every residential condenser uses one of these seven capacity codes. Find the code in your model number, read across to your tonnage. Goodman's published nomenclature maps 018 through 060 to exactly these sizes.

Capacity codeBTU/hTonnageTypical use
1818,0001.5 tonsSmall condo, big bedroom
2424,0002 tonsSmall house, ~1,000 sq ft
3030,0002.5 tonsMid-size home, ~1,500 sq ft
3636,0003 tonsTypical suburban house
4242,0003.5 tonsLarger two-story home
4848,0004 tonsLarge home, hot climate
6060,0005 tonsTop of residential range

These are nominal ratings, the industry's standard sizes. A “3-ton” unit is nominally 36,000 BTU/h, but the tested capacity with your specific indoor coil can run a few hundred BTUs either way. For any replacement or comparison, the nominal number is the right one to use.

Sponsor / Advertisement Space

Reserved ad slot for verified HVAC equipment manufacturers or energy-efficiency sponsors.

Finding the number

Where the model number actually lives

Walk out to the condenser, the big box humming in your yard or on your patio. The data plate is a metal sticker or embossed tag on the back or side panel, often near the electrical disconnect box. It lists MODEL NO., SERIAL NO., voltage, and refrigerant type in small print that has been weathering the elements for a decade. A flashlight helps.

There is one trap here, and it catches people constantly: read the MODEL number, not the SERIAL number. The serial number encodes the manufacturing date (often the year and week or month), and it is full of random-looking digits. The model number is the one with a clean capacity code in it, usually in the middle of the string.

Say the plate reads 2TTR2042A1000A on an old Trane in a Dallas garage. The product code is 2TTR, and right after it sits 42. That is 42,000 BTU/h, or 3.5 tons. That is the whole trick. Everything else in the string is series, voltage, revision, and marketing.

Decoding the three big brands

Every manufacturer uses its own alphabet soup, but the capacity code is always one of the standard values, 018 through 060. Here is how it hides inside three common model numbers, each verified against the manufacturer's own nomenclature documentation.

Carrier: 24ABB036

The last three digits 036 carry the capacity: 36,000 BTU/h, which is 3 tons. Other Carrier models like 25HBA036 use the same three-digit convention. (Per Carrier model nomenclature references.)

Trane: 2TTR2036A1000A

The digits after the product code, 36, are the capacity in thousands of BTU: 36,000 BTU/h = 3 tons. Trane catalogs list the matching row as 36 MBH (thousand BTU/h). (Per Trane product catalogs.)

Goodman: GSH130301AA or GSC140361AA

The 30 or 036 segments are the capacity code: 30,000 BTU/h = 2.5 tons, 36,000 BTU/h = 3 tons. Goodman nomenclature documents map 018, 024, 036, 042, 048, 060 to 1.5 through 5 tons. (Per Goodman spec sheets.)

See the pattern? The capacity code is always a pair or triplet from the same ladder: 24, 30, 36, 42, 48, 60 (or 024, 036, 048, 060 with a leading zero). Ignore everything around it. If you want a second opinion, punch the full model number into a search engine with the word “tonnage” — distributor spec sheets list the nominal capacity plainly.

Why you need to know this before calling a contractor

Most people first need this number when the old unit dies and a contractor asks what was there before. Knowing your tonnage puts you in control of the conversation. It also protects you: if a contractor sizes your replacement by holding a tape measure up to the old cabinet instead of reading the model number, that tells you everything about how carefully they do load calculations. Keep looking.

Here is the opinionated part. Do not let anyone talk you into “going one size up, just in case.” An oversized unit short-cycles, blasts on and off all day, and leaves the air clammy because it never runs long enough to dehumidify. The replacement should match a real load calculation, and if the old unit actually cooled the house well, its tonnage is usually the right answer to repeat.

One more use: the model number settles arguments with home inspectors, landlords, and real estate listings. A house advertised with “newer 5-ton system” that carries a 36 code is a 3-ton system, and now you know it without calling anyone.

Frequently asked questions

Where exactly do I find the model number on my AC unit?

On the outdoor condenser, look for a metal data plate or sticker, usually on the back or side panel near the electrical disconnect. It lists MODEL NO., SERIAL NO., and the electrical ratings. The indoor air handler has its own plate too, but the condenser is the one that carries the tonnage number in nearly every residential brand.

What is the difference between a model number and a serial number?

The model number describes the equipment design, including the capacity code you need (18, 24, 30, 36, 42, 48, or 60). The serial number identifies your specific unit and usually encodes the manufacturing date, not the capacity. If the two-digit number you found is, say, a week-of-manufacture figure from the serial number, your tonnage math will be nonsense. Read the line labeled MODEL.

My model number has no divisible-by-12 number in it. Now what?

Look for a longer capacity figure instead. Some brands spell out the BTU capacity directly, like 036 in Carrier nomenclature or MBH ratings on the Trane data plate. If you truly cannot find a capacity code, Google the full model number plus the word tonnage — distributor spec sheets almost always list the nominal capacity. As a last resort, the unit is listed on the AHRI directory by model number, which gives the rated capacity in BTUs.

Is the tonnage in the model number the exact cooling capacity?

It is the nominal capacity. A unit stamped 36 delivers very close to 36,000 BTU/h under rated conditions, but the true tested capacity can run a few hundred BTUs above or below depending on the matched indoor coil and the AHRI test point. For replacement sizing, the nominal number is the right one to use. It is exactly like lumber: a 2x4 is not actually 2 by 4 inches, but nobody is confused about what to buy.

Does this trick work for heat pumps too?

Yes. Heat pumps use the same convention: the capacity code in the model number is the cooling capacity in thousands of BTU/h. A Goodman GSH130301AA is a 2.5-ton heat pump, and a Trane 2TWR2036 carries the same 36 code. Note that the heating capacity of a heat pump is a separate, lower number on cold days — but that is not what the model-number code encodes.

My old unit died and the plate is unreadable. How do I size the replacement?

Do not just buy whatever was there last time, especially if the old system was original to a house built decades ago. A proper Manual J load calculation measures your windows, insulation, and air leakage and tells you the actual tonnage you need today. Replacing blindly is how oversized equipment ends up short-cycling for the next fifteen years.

Sponsor / Advertisement Space

Reserved ad slot for verified HVAC equipment manufacturers or energy-efficiency sponsors.

Related HVAC Calculators